5%%A
Telefonnummer  +49 9135 73666 65
Merkliste Klammer auf0Klammer zu
Deutsche Sprache
Mobile Menu
Mobile Menu
Articles added
5%%E
6%%A
6%%E

Fluid sensors

The fluid sensors from Optek Technology are suitable for the detection of different tube diameters and are used for non-contact detection of oils, blood or water. The system detects whether liquid is present in the hose or whether bubbles are forming in the hose. Depending on the series, an opaque plastic housing is used, which improves the ambient light correction of the fluid sensors.
Fluid sensors
Filter  (14/14 Product)
Sorting
Series
View
3%%A
3%%E
  • Manufacturer
  • Model
  • Tube Size [mm]
       -   

  • Tube Size [inch]
  • on/off Ratio
       -   

  • min. Ic(on) @ If=5mA [mA]
       -   

  • typ. Ic(on) @ If=5mA [mA]
       -   

  • max. Ic(on) @ If=5mA [mA]
       -   

  • If [mA]
       -   

  • If Peak [mA]
       -   

  • Lead Spacing [mm]
       -   

  • Length [mm]
       -   

  • Width [mm]
       -   

  • Heigth [mm]
       -   

  • Min. operating temperature [°C]
       -   

  • Max. operating temperature [°C]
       -   

2%%A
2%%E
Reset all filters [x]
Sorting
Series
OPTEK Technology
AUTO- Calibration Circuit
Datasheet:OCB100AZ PDF
Manufacturer OPTEK Technology
Model: -
Tube Size: -
Tube Size: -
on/off Ratio: -
min. Ic(on) @ If=5mA: -
typ. Ic(on) @ If=5mA: -
max. Ic(on) @ If=5mA: -
If: -
If Peak: -
Lead Spacing: -
Length: 28.6 mm
Width: 26.0 mm
Heigth: 10.4 mm
Min. operating temperature: -40 °C
Max. operating temperature: 85 °C
OPTEK Technology
AUTO-Calibration Design Kit | Schlauch Ø 1,6mm
Datasheet:OCB350L062Z PDF
Manufacturer OPTEK Technology
Model: With Design Kit
Tube Size: 1,6 mm
Tube Size: 1/16" inch
on/off Ratio: 3
min. Ic(on) @ If=5mA: 0,3 mA
typ. Ic(on) @ If=5mA: 0,8 mA
max. Ic(on) @ If=5mA: 1,3 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: -
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
AUTO-Calibration Design Kit | Schlauch Ø 3,2mm
Datasheet:OCB350L125Z PDF
Manufacturer OPTEK Technology
Model: With Design Kit
Tube Size: 3,2 mm
Tube Size: 1/8" inch
on/off Ratio: 2,5
min. Ic(on) @ If=5mA: 1,3 mA
typ. Ic(on) @ If=5mA: 2,6 mA
max. Ic(on) @ If=5mA: 3,9 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: -
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
AUTO-Calibration Design Kit | Schlauch Ø 4,8mm
Datasheet:OCB350L187Z PDF
Manufacturer OPTEK Technology
Model: With Design Kit
Tube Size: 4,8 mm
Tube Size: 3/16" inch
on/off Ratio: 2,3
min. Ic(on) @ If=5mA: 1 mA
typ. Ic(on) @ If=5mA: 2 mA
max. Ic(on) @ If=5mA: 4 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: -
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
AUTO-Calibration Design Kit | Schlauch Ø 6,3mm
Datasheet:OCB350L250Z PDF
Manufacturer OPTEK Technology
Model: With Design Kit
Tube Size: 6,3 mm
Tube Size: 1/4" inch
on/off Ratio: 2,3
min. Ic(on) @ If=5mA: 0,75 mA
typ. Ic(on) @ If=5mA: 1,5 mA
max. Ic(on) @ If=5mA: 3 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: -
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 3,2 mm | PCB Mont.
Datasheet:OPB350 PDF
Manufacturer OPTEK Technology
Model: PCB Mount
Tube Size: 3,2 mm
Tube Size: 1/8" inch
on/off Ratio: 3
min. Ic(on) @ If=5mA: 1 mA
typ. Ic(on) @ If=5mA: 3,5 mA
max. Ic(on) @ If=5mA: 6 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 8,13 ±0,25 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 1,6 mm | PCB Mont.
Datasheet:OPB350L062 PDF
Manufacturer OPTEK Technology
Model: PCB Mount
Tube Size: 1,6 mm
Tube Size: 1/16" inch
on/off Ratio: 3
min. Ic(on) @ If=5mA: 0,3 mA
typ. Ic(on) @ If=5mA: 0,8 mA
max. Ic(on) @ If=5mA: 1,3 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 3,2 mm | PCB Mont.
Datasheet:OPB350L125 PDF
Manufacturer OPTEK Technology
Model: PCB Mount
Tube Size: 3,2 mm
Tube Size: 1/8" inch
on/off Ratio: 2,5
min. Ic(on) @ If=5mA: 1,3 mA
typ. Ic(on) @ If=5mA: 2,6 mA
max. Ic(on) @ If=5mA: 3,9 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 4,8 mm | PCB Mont.
Datasheet:OPB350L187 PDF
Manufacturer OPTEK Technology
Model: PCB Mount
Tube Size: 4,8 mm
Tube Size: 3/16" inch
on/off Ratio: 2,3
min. Ic(on) @ If=5mA: 1 mA
typ. Ic(on) @ If=5mA: 2 mA
max. Ic(on) @ If=5mA: 4 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 ±0,25 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 6,3 mm | PCB Mont.
Datasheet:OPB350L250 PDF
Manufacturer OPTEK Technology
Model: PCB Mount
Tube Size: 6,3 mm
Tube Size: 1/4" inch
on/off Ratio: 2,3
min. Ic(on) @ If=5mA: 0,75 mA
typ. Ic(on) @ If=5mA: 1,5 mA
max. Ic(on) @ If=5mA: 3 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 ±0,25 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 1,6 mm | Mit Kabel
Datasheet:OPB350W062Z PDF
Manufacturer OPTEK Technology
Model: Wired assembly
Tube Size: 1,6 mm
Tube Size: 1/16" inch
on/off Ratio: 3
min. Ic(on) @ If=5mA: 0,3 mA
typ. Ic(on) @ If=5mA: 0,5 mA
max. Ic(on) @ If=5mA: 1,3 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
OPTEK Technology
Flüssigkeitssensor | Schlauch Ø 3,2 mm | Mit Kabel
Datasheet:OPB350W125Z PDF
Manufacturer OPTEK Technology
Model: Wired assembly
Tube Size: 3,2 mm
Tube Size: 1/8" inch
on/off Ratio: 2,5
min. Ic(on) @ If=5mA: 1,3 mA
typ. Ic(on) @ If=5mA: 2,6 mA
max. Ic(on) @ If=5mA: 3,9 mA
If: 50 mA
If Peak: 1000 mA
Lead Spacing: 12,04 mm
Length: -
Width: -
Heigth: -
Min. operating temperature: -
Max. operating temperature: -
Hint: current revision of the supplier datasheet is applicable

Design-In Support

Do you have questions about our Fluid sensors products or are you looking for alternatives? As an authorized distributor, we maintain a very close exchange with our manufacturers and will be happy to advise you on the selection of suitable components and possible adaptations with our many years of experience. Talk to us!
Support
<

Our Fluid sensors-Manufacturer

Brochures, flyers and presentations

Industrial Sensing and Control
  PDF   | Sites: 48 | 9.9 MB
Download
Optoelectronics Selection Guide
  PDF   | Sites: 60 | 16.8 MB
Download
2%%A
2%%E
1%%A
1%%E
1%%A
1%%E
4%%A
4%%E
7%%A
7%%E